Common quality problems in grid structure engineering
Common quality problems in grid structure engineering
Common quality problems of grid structure engineering
(1) bending deformation or local fracture of the bar;
(2) The connection of sealing plate or cone head weld is damaged;
(3) The joint is deformed or fractured;

(4) The weld is not full or there are bubbles, slag inclusion and micro cracks, which exceed the specified standard;
(5) The high strength bolt is broken or pulled out from the ball joint;
(6) The members collide at the nodes, and the web member of the support collides with the supporting structure when the upper chord is supported;
(7) The displacement of bearing node;
(8) the deflection of grid structure is too large, exceeding 1.15 times of the corresponding design value specified in the design.